disperator
      



Timers

There are four optional timers available that may be included into the control circuit to regulate the time the disposer's motor and/or the solenoid valve for flushing water operates. Timers run on voltages between 24V to 240V therefore transformers are required for marine installations.

Option 1: Pre-set time for different running periods for the disposer and water
The operation is started by pressing the start button. Initially, the motor and the flushing water run simultaneously for a pre-set time after which the motor stops. The flushing water continues to run for a further pre-set period after the motor has stopped. The running time for both timers is adjustable. Automatically prolonging the period the water runs through the system after the disposer has stopped, will flush away any remaining food waste without any manual supervision by the operator.

Product sheet: TIM-00-01-01

Option 2: Pre-set time for stopping the disposer and flushing water 
The operation is started by pressing the start button. The motor and the flushing water run together for a pre-set period after which the motor and the flushing water stop simultaneously. The running period for the timer is adjustable. This operation is helpful when the operator must leave the disposer unattended before the grinding process is completed.

Product sheet: TIM-00-02-01

Option 3: Pre-set intervals for repetitive running of disposer and water
The operation is started by pressing the start button. The motor and flushing water run together at a pre-set adjustable interval in repetitive cycles. The running and pause intervals are pre-set and adjustable according to the requirements of the operation. The operation is stopped by pressing the stop button. This type of operation is useful in washing up areas where the disposer is used for long periods of time and the excessive use of water must be limited.

Product sheet: TIM-00-03-01

Option 4: Pre-set time for flushing water after manually stopping disposer
The process is started by pressing the start button. After the food waste grinding process is completed the operator presses the stop button. The motor stops but water continues to flush a pre-set period afterwards. The running period for the timer is adjustable. This timer function prolongs the period water flushes after the disposer has been manually stopped. This removes any remaining food waste still in the system.

Product sheet: TIM-00-04-01